2023 Generac 22KW Protector QS #RG022

Call for Price

Call for Price

Overview

Availability Brochure
Year2023
MakeGenerac
Model22KW Protector QS #RG022

Product Features

Description

Automatic Backup Power For Large or Custom Homes



Looking to back up your entire home, or more items than usual? Consider the Protector gaseous automatic backup generator line. These units powers essential appliances and modern technologies during power outages, allowing homeowners and their families to continue living life comfortably and without interruption.



What Makes the Protector Series Such a Great Choice?



Generac's Protector Series offers benefits that competitors can’t match. Installation flexibility and cost reduction. Sophisticated, yet intuitive controls. Quiet operation. Supported by a 24/7/365 customer support team at our corporate headquarters, and a nationwide dealer network of more than 6,000 strong.

Key Features
  • The best liquid cooled engine packs more power into a smaller footprint - ideal when space is a premium. The neutral styling, color and small footprint fits unobtrusively into landscaping. Clean burning, continuous fuel choice of natural gas to LP.
  • True Power™ Technology: Delivers best-in class power quality with less than 5% total harmonic distortion (THD) for clean, smooth operation of sensitive electronics and appliances.
  • Evolution™ Controller: A cutting-edge, intuitive control. The Evolution controller features a multilingual, two-line LCD text display with color-coded, backlit buttons. It has received upgrades, including USB flash capability, smart battery charging, voltage adjustment, and backlit membrane pad style buttons.
  • 5-year limited warranty with extended warranty options available: We are proud of our innovative product design, high quality and first-class reliability so we stand behind them with a strong 5, 7 or 10-year limited
  • Can Be Installed Just 18" From a Structure: Capability to be installed 18 inches away from a structure, ideal for areas with tight lot lines.  Generac’s is the only manufacturer of standby generators to have 18” offset on most of its residential lineup.
  • Tough, Durable All-Aluminum Enclosures: Our RhinoCoat™ powder-coated finish helps make corrosion-resistant aluminum perfect for all weather conditions.
  • Quiet-Test™: All backup generators run a weekly test to ensure the system is running properly. Thanks to Quiet-Test, your Protector Series home generator runs its self-test at a lower, quieter RPM, which can be programmed to run weekly, bi-weekly, or monthly.
  • Mobile Link™ Connectivity: Comes standard with all Protector Series generators. Mobile Link allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet or PC. Easily access information, such as the current operating status and the generator’s maintenance schedule.
  • Additional Features: Improved stub ups and electrical connection access decrease installation costs. All connections are dual conductor rated, and the implementation of quick connects for the control wires, completely eliminates the need for crimping or lugging. Improved customer connection access, which decreases installation costs.
Generator Specifications
  • Rotor Insulation Class: H
  • Stator Insulation Class: H
  • Telephone Interference Factor (TIF): <50
  • Alternator Output Leads 1-Phase: 4 wire
  • Alternator Output Leads 3-Phase: 6 wire
  • Bearings: Sealed Ball
  • Coupling: Flexible Disc
  • Excitation System: Direct
Voltage Regulation
  • Type: Electronic
  • Sensing: Single Phase
  • Regulation: ±1%
Governor Specifications
  • Type: Electronic
  • Frequency Regulation: Isochronous
  • Steady State Regulation: ± 0.25%
Electrical System
  • Battery Charge Alternator: 12 Volt 30 Amp
  • Static Battery Charger: 2.5 Amp
  • Recommended Battery (battery not included): Group 26
  • System Voltage: 12 Volts
Generator Features
  • Revolving field heavy duty generator
  • Directly connected to the engine
  • Operating temperature rise 120 °C above a 40 °C ambient
  • Class H insulation is NEMA rated
  • Class F insulation is NEMA rated
  • All models fully prototyped tested
Enclosure Features
  • Aluminum weather protective enclosure: Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.
  • Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • Small, compact, attractive: Makes for an easy, eye appealing installa-tion.
  • SAE: Sound attenuated enclosure ensures quiet operation.
Engine Specifications
  • Make: Generac
  • Model: In-line
  • Cylinders: 4
  • Displacement (Liters): 2.4
  • Bore: 3.41 in. (86.5 mm)
  • Stroke: 3.94 in. (100 mm)
  • Compression Ratio: 9.5:1
  • Intake Air System: Naturally Aspirated
  • Lifter Type: Hydraulic
Engine Lubrication Sysrem
  • Oil Pump Type: Gear
  • Oil Filter Type: Full flow spin-on cartridge
  • Crankcase Capacity: 4 qt (3.8 l)
Engine Cooling System
  • Type: Closed
  • Water Pump: Belt driven
  • Fan Speed: 1,980 RPM
  • Fan Diameter: 18.1 in. (459.7 mm)
  • Fan Mode: Pusher
Fuel System
  • Fuel Type: Natural gas, propane vapor
  • Carburetor: Down Draft
  • Secondary Fuel Regulator: Standard
  • Fuel Shut Off Solenoid: Standard
  • LP Fuel Pressure: 5-14 in Water Column
  • NG Fuel Pressure: 5-14 in Water Column
Generator Output Voltage/kW - 60 Hz
  • 120 / 240 V, 10, 1.0 pf: kW LPG: 22; Amp LPG: 92; kW Nat. Gas: 22; Amp Nat. Gas: 92; CB Size (Both): 100
  • 120 / 208 V, 30, 0.8 pl: kW LPG: 22; Amp LPG: 76; kW Nat. Gas: 22; Amp Nat. Gas: 76; CB Size (Both): 80
  • 120 / 240 V, 30, 0.8 pf: kW LPG: 22; Amp LPG: 66; kW Nat. Gas: 22; Amp Nat. Gas: 66; CB Size (Both): 80
Surge Capacity in Amps
  • 120/240 V, 10: (15%) 55; (30%) 135
  • 120/208 V, 30: (15%) 40; (30%) 92
  • 120/240 V, 30: (15%) 35; (30%) 80
Engine Fuel Consumption
  • Exercise cycle: Natural Gas - 42 ft³/hr; 1.2 m³/hr; 0.44 gal/hr; Propane - 16 ft³/hr; 1.7 l/hr
  • 25% of rated load: Natural Gas - 100 ft³/hr; 2.8 m³/hr; 1.1 gal/hr; Propane - 40 ft³/hr; 4.2 l/hr
  • 50% of rated load: Natural Gas - 190 ft³/hr; 5.4 m³/hr; 2.1 gal/hr; Propane - 75 ft³/hr; 7.8 l/hr
  • 75% of rated load: Natural Gas - 255 ft³/hr; 7.2 m³/hr; 2.8 gal/hr; Propane - 101 ft³/hr; 10.5 l/hr
  • 100% of rated load: Natural Gas - 316 ft³/hr; 9 m³/hr; 3.4 gal/hr; Propane - 125 ft³/hr; 13 l/hr
Engine Cooling
  • Air flow (inlet air including alternator and combustion air): 2,400 in. cfm (68cmm)
  • System coolant capacity: 2.5 gal. (9.5 L)
  • Heat rejection to coolant: 99,000 BTU per hr (104.5 MJ per hr)
  • Maximum operation air temperature on radiator: 140°F (60 °C)
  • Maximum ambient temperature: 122°F (50 °C)
Combustion Requirements
  • Flow at rated power: 68 cfm (1.9 cmm)
Sound Emissions
  • Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* : 61
  • Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load*: 70
Exhaust
  • Exhaust flow at rated output: 165 cfm (4.7 cmm)
  • Exhaust temperature at muffler outlet: 900 °F (482 °C)
Engine Parameters
  • Rated Synchronous: 1800 rpm
Power Adjustment for Ambient Conditions
  • Temperature Deration: 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F
  • Altitude Deration: 1% for every 100 m above 183 m or 3% for every 1,000 ft above 600 ft
Controller Features
  • Two-Line Plain Text LCD Display: Simple user interface for ease of operation
  • Mode Switch: Auto - Automatic Start on Utility failure 7 day exerciser ; Off - Stops unit Power is removed Control and charger still operate ; Manual - Start with starter control, unit stays on If utility fails, transfer to load takes place
  • Programmable start delay between 10-30 seconds: 10 sec standard
  • Engine Start Sequence: Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
  • Engine Warm-up: 5 sec
  • Engine Cool-Down: 1 min
  • Starter Lock-out: Starter cannot re-engage until 5 sec after engine has stopped
  • Smart Battery Charger: Standard
  • Automatic Voltage Regulation with Over and Under Voltage Protection: Standard
  • Automatic Low Oil Pressure Shutdown: Standard
  • Overspeed Shutdown: Standard, 72 Hz
  • High Temperature Shutdown: Standard
  • Overcrank Protection: Standard
  • Safety Fused: Standard
  • Failure to Transfer Protection: Standard
  • Low Battery Protection: Standard
  • 50 Event Run Log: Standard
  • Future Set Capable Exerciser: Standard
  • Incorrect Wiring Protection: Standard
  • Internal Fault Protection: Standard
  • Common External Fault Capability: Standard
  • Governor Failure Protection: Standard
Remote Monitoring
  • Ability to view generator status: Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind.
  • Ability to view generator Exercise/Run and Total Hours: Review the generator's complete protection profile for exercise hours and total hours.
  • Ability to view generator maintenance information: Provides maintenance information for the specific model generator when scheduled maintenance is due.
  • Monthly report with previous month's activity: Detailed monthly reports provide historical generator information.
  • Ability to view generator battery information: Built in battery diagnostics displaying current state of the battery.
  • Weather information: Provides detailed local ambient weather conditions for generator location.

Engine

Engine Type In-line, 4 Cylinders
Displacement 2.4 L

Other

Noise Level At normal load: 70; In exercise mode: 61